Myers SKHS Series Sewage Pumps Buyers Guides & Review

The Myers submersible SKHS series of sewage pumps is specifically designed to meet the demands of wastewater and sewage handling in residential and commercial building applications. The SKHS series has a powerful motor that is available in 1/2, 1, 1-1/2, or 2 horsepower. This series has a standard 2 inch NPT discharge. A 3 inch discharge is optional.

This series features a non-clogging, two-vane, semi-open cast iron impeller, which is threaded to a stainless steel shaft and handles applications involving higher capacities and heads. It is capable of handling up to 2 inch spherical solids and lint. A precision carbon and ceramic-faced mechanical shaft seal that is extensively lapped, provides for a long, leak-proof life.

The Myers SKHS series has an oil-filled motor that provides superior cooling characteristics, allowing the motor to run cool and quiet for years. This oil-filled design also provides permanent lubrication of the shaft bearings, minimizing maintenance and extending the service life of the pump.

In addition, to protect against overheating, single-phase motor windings contain an automatic reset thermal overload; three phase motors require a magnetic starter with overload protection located in the accessory control panel.

Features

• Water-resistant power cord with molded plug is available in 20 or 30 foot lengths.

• Upper and lower bearings support motor shaft, minimizing the effects of impeller thrust loads. This design results in minimum friction and perfect alignment of rotor, for longer service from the pump.

• Oil-filled motor provides superior cooling and permanent lubrication of bearings, minimizing maintenance and extending service life.

• 1/2, 1, 1-1/2 and 2 horsepower capacitor start motors provide maximum starting torque. Motor windings contain automatic thermal overload protection (1ø).

• Heavy-duty, cast iron construction provides long life and assists in heat dissipation for cooler motor operation.

• Precision, mechanical shaft seal is extensively lapped, carbon and ceramic faced for a long leak- proof life.

• The non-clogging, two-vane, semi-open cast iron impeller, which is threaded to a stainless steel shaft, operates with higher capacities and heads, capability of passing 2 inch diameter spherical solids. Pump-out vanes on back of impeller prevent stringy materials from binding impeller or shaft.

• Discharge is standard 2 inch NPT (3 inch is optional).

• Bottom suction inlet has no screen to become clogged, providing optimum pump performance and minimal maintenance.

MYERS SKHS SERIES SEWAGE PUMPS
myers skhs series sewage pumps
Myers SKHS Series Sewage Pumps

Model Comparison Chart

Model Discharge (NPT Vertical) HP Voltage Phase GPM Max. Head
MSKHS50M7 30 2″ 1/2 200 1 144 45′
MSKHS50M2 20 2″ 1/2 230 1 144 45′
MSKHS50M1 20 2″ 1/2 115 1 144 45′
MSKHS50M2 30 2″ 1/2 230 1 144 45′
MSKHS100M2 20 2″ 1 230 1 160 57′
MSKHS50M1 30 2″ 1/2 115 1 144 45′
MSKHS100M2 30 2″ 1 230 1 160 57′
MSKHS50A1 20 2″ 1/2 115 1 144 45′
MSKHS50A2 20 2″ 1/2 230 1 144 45′
MSKHS50M4 20 2″ 1/2 460 3 144 45′
MSKHS50M7 20 2″ 1/2 200 1 144 45′
MSKHS50M3 20 2″ 1/2 230 3 144 45′
MSKHS50M6 20 2″ 1/2 200 3 144 45′
MSKHS50M4 30 2″ 1/2 460 3 144 45′
MSKHS100M4 20 2″ 1 460 3 160 57′
MSKHS50M3 30 2″ 1/2 230 3 144 45′
MSKHS50M6 30 2″ 1/2 200 3 144 45′
MSKHS100M3 20 2″ 1 230 3 160 57′
MSKHS100A2 20 2″ 1 230 1 160 57′
MSKHS100M4 30 2″ 1 460 3 160 57′
MSKHS100M3 30 2″ 1 230 3 160 57′
MSKHS50A7 20 2″ 1/2 200 1 144 45′
MSKHS100M6 20 2″ 1 200 3 160 57′
MSKHS100M7 20 2″ 1 200 1 160 57′
MSKHS150M2 20 2″ 1-1/2 230 1 148 70′
MSKHS100M7 30 2″ 1 200 1 160 57′
MSKHS100A7 20 2″ 1 200 1 160 57′
MSKHS100M6 30 2″ 1 200 3 160 57′
MSKHS150M2 30 2″ 1-1/2 230 1 148 70′
MSKHS150M4 20 2″ 1-1/2 460 3 148 70′
MSKHS150A2 20 2″ 1-1/2 230 1 148 70′
MSKHS150M3 20 2″ 1-1/2 230 3 148 70′
MSKHS150M4 30 2″ 1-1/2 460 3 148 70′
MSKHS150M3 30 2″ 1-1/2 230 3 148 70′
MSKHS200M2 20 2″ 2 230 1 170 80′
MSKHS150M7 20 2″ 1-1/2 200 1 148 70′
MSKHS150M6 20 2″ 1-1/2 200 3 148 70′
MSKHS150M7 30 2″ 1-1/2 200 1 148 70′
MSKHS150M6 30 2″ 1-1/2 200 3 148 70′
MSKHS200M2 30 2″ 2 230 1 170 80′
MSKHS150A7 20 2″ 1-1/2 200 1 148 70′
MSKHS200M4 20 2″ 2 460 3 170 80′
MSKHS200M3 20 2″ 2 230 3 170 80′
MSKHS200M3 30 2″ 2 230 3 170 80′
MSKHS200M4 30 2″ 2 460 3 170 80′
MSKHS200M6 20 2″ 2 200 3 170 80′
MSKHS200M6 30 2″ 2 200 3 170 80′
PERFORMANCE CURVE

myers skhs series sewage pumps curves

TROUBLESHOOTING

myers skhs series sewage pumps troubleshooting

DIMENSIONS

myers skhs series sewage pumps dimensions

MATERIALS OF CONSTRUCTION

myers skhs series sewage pumps materials

REPAIR PARTS

myers skhs series sewage pumps repair parts

BROCHURE
Myers SKHS Series Sewage Pump Brochure
INSTALLATION MANUAL
Myers SKHS Series Sewage Pump Installation Manual
CURVES
Myers SKHS Series Sewage Pump Curves

Pump Products application engineers are standing by to help you find the right pump, as well as to provide price quotes, stocking availability and shipping information. Call our toll free number 1-800-429-0800 to speak to an expert today.