hazardous location pump Archives - PumpProducts.com
  • Zoeller X840 Series Grinder Pumps Buyers Guide & Review

    April 10, 2019

    This series of submersible grinder pumps is designed for use in residential or commercial wastewater applications in Class I, Division 1, Groups C and D environments. Each pump is FM/CSA approved and features innovative motor and electrical enclosures that are designed to reduce the risk of vapor ignition both inside and outside the pump. Should vapors inside the electrical enclosures become ignited, the enclosures are engineered to contain the event and prevent escalation. Each pump is constructed of hardware that will allow it to operate safely and efficiently in extreme conditions. As with every Zoeller pump, each one is 100% factory tested to ensure quality and reliability for years of trouble free performance! This attention to detail is an inherent feature of every pump in this series, making it one of the most reliable in the industry. Features Surface temperature code T5 (1 Ph) or T6 (3 Ph). Includes a stainless steel lifting bracket for easy installation and removal. All models are hermetically sealed to be watertight, dust-tight, and completely submersible. ZOELLER X840 SERIES GRINDER PUMPS Model Comparison Chart Model Discharge (NPT Vertical) HP Voltage Phase GPM Max. Head FX840 1-1/4" 2 230 3 45 104' GX840 1-1/4" 2 460 3 45 104' JX840 1-1/4" 2 200-208 3 45 104' EX840 1-1/4" 2 230 1 45 104' IX840 1-1/4" 2 200-208 1 45 104' FX841 1-1/4" 2 230 3 59 125' FX842 1-1/4" 2 230 3 34 125' GX841 1-1/4" 2 460 3 59 125' GX842 1-1/4" 2 460 3 34 125' JX841 1-1/4" 2 200-208 3 59 125' JX842 1-1/4" 2 200-208 3 34 125' EX841 1-1/4" 2 230 1 59 125' EX842 1-1/4" 2 230 1 34 125' IX841 1-1/4" 2 200-208 1 59 125' IX842 1-1/4" 2 200-208 1 34 125' PERFORMANCE CURVES DIMENSIONS SERVICE CHECKLIST SPECIFICATIONS TDH FLOW PER MINUTE BROCHURE Zoeller X840 Series Grinder Pumps Brochure OWNER'S MANUAL Zoeller X840 Series Grinder Pumps Owners Manual TECHNICAL DATA Zoeller X840 Series Grinder Pumps Technical Data Pump Products application engineers are standing by to help you find the right pump, as well as to provide price quotes, stocking availability and shipping information. Call our toll free number 1-800-429-0800 to speak to an expert today.

    VIEW
  • Zoeller X600 Series Sewage Pumps Buyers Guide & Review

    April 10, 2019

    This series of submersible pumps is designed for use in residential, commercial, or industrial wastewater applications in Class I, Division 1, Group C, and D locations. Each pump is FM/CSA approved and features innovative motor and electrical enclosures that are designed to reduce the risk of vapor ignition both inside and outside the pump. Should vapors inside the electrical enclosures become ignited, the enclosures are engineered to contain the event and prevent escalation. Each pump is constructed of hardware that will allow it to operate safely and efficiently in extreme conditions. As with every Zoeller pump, each one is 100% factory tested to ensure quality and reliability for years of trouble free performance! This attention to detail is an inherent feature of every pump in this series, making it one of the most reliable in the industry. Features All units require a control panel with intrinsically safe relays and a moisture indicator. Surface temperature code T5 (1 Ph) or T6 (3 Ph). An optional lifting bail is available for easy installation and removal. All models are hermetically sealed to be watertight, dust-tight, and completely submersible. Reserve Powered Design: For unusual conditions, a reserve safety factor is engineered into the design of every pump. APPLICATIONS Pumping Station. Storm Water Removal. All Wastewater Removal. Industrial Waste. Warning: Not for use in acidic atmospheres. ZOELLER X600 SERIES SEWAGE PUMPS Model Comparison Chart Model Discharge (NPT) HP Voltage Phase GPM Max. Head 611-0024 3" Vertical 1 230 3 250 22' 611-0025 3" Flange Horizontal 1 230 3 250 22' 611-0022 3" Horizontal 1 200 3 250 22' 611-0029 4" Flange Horizontal 1 460 3 250 22' 611-0026 4" Flange Horizontal 1 230 3 250 22' 611-0027 3" Vertical 1 460 3 250 22' 611-0021 3" Vertical 1 200 3 250 22' 611-0023 4" Flange Horizontal 1 200 3 250 22' 611-0028 3" Flange Horizontal 1 460 3 250 22' 621-0029 3" Vertical 1-1/2 460 3 320 29' 621-0025 4" Flange Horizontal 1-1/2 200 3 320 29' 621-0028 4" Flange Horizontal 1-1/2 230 3 320 29' 621-0027 3" Flange Horizontal 1-1/2 230 3 320 29' 621-0030 3" Flange Horizontal 1-1/2 460 3 320 29' 621-0024 3" Flange Horizontal 1-1/2 200 3 320 29' 621-0026 3" Vertical 1-1/2 230 3 320 29' 621-0031 4" Flange Horizontal 1-1/2 460 3 320 29' 621-0023 3" Vertical 1-1/2 200 3 320 29' 631-0029 4" Flange Horizontal 2 230 3 390 34' 631-0025 3" Flange Horizontal 2 200 3 390 34' 631-0028 3" Flange Horizontal 2 230 3 390 34' 631-0030 3" Vertical 2 460 3 390 34' 631-0024 3" Vertical 2 200 3 390 34' 631-0027 3" Vertical 2 230 3 390 34' 631-0032 4" Flange Horizontal 2 460 3 390 34' 631-0031 3" Flange Horizontal 2 460 3 390 34' 631-0026 4" Flange Horizontal 2 200 3 390 34' 641-0030 3" Vertical 3 200 3 460 44' 641-0034 3" Flange Horizontal 3 230 3 460 44' 641-0037 3" Flange Horizontal 3 460 3 460 44' 641-0033 3" Vertical 3 230 3 460 44' 641-0031 3" Flange Horizontal 3 200 3 460 44' 641-0038 4" Flange Horizontal 3 460 3 460 44' 641-0035 4" Flange Horizontal 3 230 3 460 44' 641-0036 3" Vertical 3 460 3 460 44' 611-0020 4" Flange Horizontal 1 230 1 250 22' 611-0018 3" Vertical 1 230 1 250 22' 611-0019 3" Flange Horizontal 1 230 1 250 22' 641-0032 4" Flange Horizontal 3 200 3 460 44' 621-0020 3" Vertical 1-1/2 230 1 320 29' 621-0022 4" Flange Horizontal 1-1/2 230 1 320 29' 621-0021 3" Flange Horizontal 1-1/2 230 1 320 29' 631-0021 3" Vertical 2 230 1 390 34' 631-0023 4" Flange Horizontal 2 230 1 390 34' 631-0022 3" Flange Horizontal 2 230 1 390 34' 641-0028 3" Flange Horizontal 3 230 1 420 39' 641-0029 4" Flange Horizontal 3 230 1 420 39' 641-0027 3" Vertical 3 230 1 420 39' 651-0027 4" Flange Horizontal 5 200 3 533 54' 651-0025 3" Vertical 5 200 3 533 54' 651-0028 3" Vertical 5 230 3 533 54' 651-0029 3" Flange Horizontal 5 230 3 533 54' 651-0031 3" Vertical 5 460 3 533 54' 651-0026 3" Flange Horizontal 5 200 3 533 54' 651-0030 4" Flange Horizontal 5 230 3 533 54' 651-0033 4" Flange Horizontal 5 460 3 533 54' 651-0032 3" Flange Horizontal 5 460 3 533 54' 651-0024 4" Flange Horizontal 5 230 1 475 46' 651-0022 3" Vertical 5 230 1 475 46' 651-0023 3" Flange Horizontal 5 230 1 475 46' 661-0024 3" Vertical 7-1/2 230 3 600 65' 661-0022 3" Flange Horizontal 7-1/2 200 3 600 65' 661-0029 4" Flange Horizontal 7-1/2 460 3 600 65' 661-0025 3" Flange Horizontal 7-1/2 230 3 600 65' 661-0026 4" Horizontal Flanged 7-1/2 230 3 600 65' 661-0023 4" Flange Horizontal 7-1/2 200 3 600 65' 661-0028 3" Flange Horizontal 7-1/2 460 3 600 65' 661-0027 3" Vertical 7-1/2 460 3 600 65' 661-0021 3" Vertical 7-1/2 200 3 600 65' PERFORMANCE CURVES DIMENSIONS SERVICE CHECKLIST SPECIFICATIONS TDH FLOW PER MINUTE OWNER'S MANUAL Zoeller X600 Series Sewage Pumps Owners Manual BROCHURE Zoeller X600 Series Sewage Pumps Brochure SPECIFICATIONS Zoeller X600 Series Sewage Pumps Specifications TECHNICAL DATA Zoeller X600 Series Sewage Pumps Technical Data PERFORMANCE CURVE Zoeller X600 Series Sewage Pumps Performance Curve Pump Products application engineers are standing by to help you find the right pump, as well as to provide price quotes, stocking availability and shipping information. Call our toll free number 1-800-429-0800 to speak to an expert today.

    VIEW
  • Zoeller X400 Series Sewage Pumps Buyers Guide & Review

    April 9, 2019

    This series of submersible pumps is designed for use in residential or commercial wastewater applications in Class I, Division 1, Group C, and D locations. Each pump is FM/CSA approved and features innovative motor and electrical enclosures that are designed to reduce the risk of vapor ignition both inside and outside the pump. Should vapors inside the electrical enclosures become ignited, the enclosures are engineered to contain the event and prevent escalation. Each pump is constructed of hardware that will allow it to operate safely and efficiently in extreme conditions. As with every Zoeller pump, each one is 100% factory tested to ensure quality and reliability for years of trouble free performance! This attention to detail is an inherent feature of every pump in this series, making it one of the most reliable in the industry. Features Requires a Zoeller control panel with intrinsically safe relays and a moisture indicator. Surface temperature code T5 (1 Ph) or T6 (3 Ph). Includes a stainless steel lifting bracket for easy installation and removal. All models are hermetically sealed to be watertight, dust-tight, and completely submersible. ZOELLER X400 SERIES SEWAGE PUMPS Model Comparison Chart Model Discharge (NPT Flange Horizontal) HP Voltage Phase GPM Max. Head EX404 4" 2 230 1 300 33' IX404 4" 2 200-208 1 300 33' JX404 4" 2 200-208 3 300 33' FX404 4" 2 230 3 300 33' GX404 4" 2 460 3 300 33' EX405 4" 3 230 1 361 38' IX405 4" 3 200-208 1 361 38' FX405 4" 3 230 3 361 38' JX405 4" 3 200-208 3 361 38' GX405 4" 3 460 3 361 38' PERFORMANCE CURVES DIMENSIONS SERVICE CHECKLIST SPECIFICATIONS TDH FLOW PER MINUTE OWNER'S MANUAL Zoeller X400 Series Sewage Pumps Owners Manual SPECIFICATIONS Zoeller X400 Series Sewage Pumps Specifications TECHNICAL DATA Zoeller X400 Series Sewage Pumps Technical Data WIRING DIAGRAM Zoeller X400 Series Sewage Pumps Wiring Diagram Pump Products application engineers are standing by to help you find the right pump, as well as to provide price quotes, stocking availability and shipping information. Call our toll free number 1-800-429-0800 to speak to an expert today.

    VIEW
  • Zoeller X290 Series Sewage Pumps Buyers Guide & Review

    April 9, 2019

    This series of submersible pumps is designed for use in residential or commercial wastewater applications in Class I, Division 1, Group C and D locations. Each pump is FM/CSA approved and features innovative motor and electrical enclosures that are designed to reduce the risk of vapor ignition both inside and outside the pump. Should vapors inside the electrical enclosures become ignited, the enclosures are engineered to contain the event and prevent escalation. Each pump is constructed of hardware that will allow it to operate safely and efficiently in extreme conditions. As with every Zoeller pump, each one is 100% factory tested to ensure quality and reliability for years of trouble-free performance! Features Automatic models are available with an optional seal failure panel (P/N 10- 1031). Nonautomatic units require a Zoeller control panel with intrinsically safe relays and a moisture indicator. Surface temperature code T5 (1 Ph) or T6 (3 Ph). Includes a stainless steel lifting bracket for easy installation and removal. All models are hermetically sealed to be watertight, dust-tight, and completely submersible. ZOELLER X290 SERIES SEWAGE PUMPS Model Comparison Chart Model Discharge (NPT Flange Vertical) HP Voltage Phase GPM Max. Head NX292 2" 1/2 115 1 140 42' EX292 2" 1/2 230 1 140 42' IX292 2" 1/2 200-208 1 140 42' EX293 2" 1 230 1 118 50' JX292 2" 1/2 200-208 3 140 42' GX292 2" 1/2 460 3 140 42' FX292 2" 1/2 230 3 140 42' IX293 2" 1 200-208 1 118 50' JX293 2" 1 200-208 3 118 50' GX293 2" 1 460 3 118 50' FX293 2" 1 230 3 118 50' EX294 2" 1-1/2 230 1 196 62' IX294 2" 1-1/2 200-208 1 196 62' EX295 2" 2 230 1 214 75' IX295 2" 2 200-208 1 214 75' JX294 2" 1-1/2 200-208 3 196 62' GX294 2" 1-1/2 460 3 196 62' FX294 2" 1-1/2 230 3 196 62' HX294 2" 1-1/2 200-208 1 196 62' MX292 2" 1/2 115 1 140 42' FX295 2" 2 230 3 214 75' JX295 2" 2 200-208 3 214 75' GX295 2" 2 460 3 214 75' DX292 2" 1/2 230 1 140 42' HX292 2" 1/2 200-208 1 140 42' DX293 2" 1 230 1 118 50' DX294 2" 1-1/2 230 1 196 62' DX295 2" 2 230 1 214 75' HX295 2" 2 200-208 1 214 75' PERFORMANCE CURVES DIMENSIONS SERVICE CHECKLIST SPECIFICATIONS TDH FLOW PER MINUTE OWNER'S MANUAL Zoeller X290 Series Sewage Pumps Owners Manual SPECIFICATIONS Zoeller X290 Series Sewage Pumps Specifications TECHNICAL DATA Zoeller X290 Series Sewage Pumps Technical Data WIRING DIAGRAM Zoeller X290 Series Sewage Pumps Wiring Diagram Pump Products application engineers are standing by to help you find the right pump, as well as to provide price quotes, stocking availability and shipping information. Call our toll free number 1-800-429-0800 to speak to an expert today.

    VIEW
  • Zoeller X280 Series Sewage Pumps Buyers Guide & Review

    April 9, 2019

    This series of submersible pumps is designed for use in residential or commercial wastewater applications in Class I, Division 1, Group, and D environments. Each pump is FM/CSA approved and features innovative motor and electrical enclosures that are designed to reduce the risk of vapor ignition both inside and outside the pump. Should vapors inside the electrical enclosure become ignited, the enclosure is engineered to contain the event and prevent escalation. Each pump is constructed of hardware that will allow it to operate safely and efficiently in extreme conditions. WARNING: Not for use in acidic, methanol, or ethyl acetate atmospheres. Features Corrosion-resistant, powder coated epoxy finish Durable cast iron cover, motor adapter, and pump housing Stainless steel bolts, handle, guard and float rod guide, switch arm, and actuator assembly Stainless steel rotor shaft Includes a stainless steel lifting bracket for easy installation and removal FM listed motor for Class I, Division 1, Group C & D environments Motor - 1750 RPM, oil-filled, hermetically sealed, overload protection needs to be provided in control panel Moisture sensors prewired in motor housing (functionality requires indicator circuit in panel) Non-clogging cast iron vortex impeller design Upper ball bearing and lower ball bearing running in bath of oil Neoprene square ring seals used throughout 20 ft UL listed 8-wire neoprene cord Sensor leads & power leads in one cord for easy installation Maximum temperature for sewage or dewatering is104°F Passes 2" spherical solids Major width: 13-5/16" Major height: 23-17/32" 100% computerized testing and 100% tested submerged in water This model is also available with 25, 35 and 50 ft cord lengths Control panel with intrinsically safe relays and moisture indicator is required ZOELLER X280 SERIES SEWAGE PUMPS Model Comparison Chart Model Discharge (NPT Flange Vertical) HP Voltage Phase GPM Max. Head GX282 2" 1/2 460 3 127 26' NX282 2" 1/2 115 1 127 26' EX282 2" 1/2 230 1 127 26' IX282 2" 1/2 200-208 1 127 26' FX282 2" 1/2 230 3 127 26' JX282 2" 1/2 200-208 3 127 26' JX282 2" 1 200-208 3 179 35' EX284 2" 1 230 1 179 35' IX284 2" 1 200-208 1 179 35' GX284 2" 1 460 3 179 35' JX284 2" 1 200-208 3 179 35' FX284 2" 1 230 3 179 35' MX282 2" 1/2 115 1 127 26' DX282 2" 1/2 230 1 127 26' HX282 2" 1/2 200-208 1 127 26' DX284 2" 1 230 1 179 35' HX284 2" 1 200-208 1 179 35' PERFORMANCE CURVES DIMENSIONS SERVICE CHECKLIST SPECIFICATIONS TDH FLOW PER MINUTE OWNER'S MANUAL Zoeller X280 Series Sewage Pumps Owners Manual SPECIFICATIONS Zoeller X280 Series Sewage Pumps Specifications TECHNICAL DATA Zoeller X280 Series Sewage Pumps Technical Data WIRING DIAGRAM Zoeller X280 Series Sewage Pumps Wiring Diagram Pump Products application engineers are standing by to help you find the right pump, as well as to provide price quotes, stocking availability and shipping information. Call our toll free number 1-800-429-0800 to speak to an expert today.

    VIEW
  • Zoeller X180 & X190 Series Effluent Pumps Buyers Guide & Review

    April 8, 2019

    The X180 and X190 series of submersible pumps are designed for use in residential or commercial dewatering or effluent applications in Class I, Division 1, Group C, and D locations. Each pump is FM/CSA approved and features innovative motor and electrical enclosures that are designed to reduce the risk of vapor ignition both inside and outside the pump. Should vapors inside the electrical enclosures become ignited, the enclosures are engineered to contain the event and prevent escalation. Each pump is constructed of hardware that will allow it to operate safely and efficiently in extreme conditions. As with every Zoeller pump, each one is 100% factory tested to ensure quality and reliability for years of trouble free performance! WARNING: Not for use in acidic, methanol, or ethyl acetate atmospheres. Features Automatic models are available with an optional seal failure panel (P/N 10- 1031). Nonautomatic units require a Zoeller control panel with intrinsically safe relays and a moisture indicator. Surface temperature code T5 (1 Ph) or T6 (3 Ph). Includes a stainless steel lifting bracket for easy installation and removal. All models are hermetically sealed to be watertight, dust-tight, and completely submersible. ZOELLER X180 & X190 SERIES EFFLUENT PUMPS Model Comparison Chart Model Discharge (NPT Flange Vertical) HP Voltage Phase GPM Max. Head EX185 1-1/2" 1 230 1 85 73' IX185 1-1/2" 1 200-208 1 85 73' JX185 1-1/2" 1 200-208 1 85 73' GX185 1-1/2" 1 460 3 85 73' FX185 1-1/2" 1 230 1 85 73' EX186 1-1/2" 1-1/2 230 1 58 114' EX188 1-1/2" 1-1/2 230 1 145 91' IX186 1-1/2" 1-1/2 200-208 1 58 114' IX188 1-1/2" 1-1/2 200-208 1 145 91' EX191 1-1/2" 2 230 1 45 137' EX189 1-1/2" 2 230 1 145 110' GX186 1-1/2" 1-1/2 460 3 58 114' FX186 1-1/2" 1-1/2 230 3 58 114' JX186 1-1/2" 1-1/2 200-208 3 58 114' IX189 1-1/2" 2 200-208 1 145 110' GX188 1-1/2" 1-1/2 460 3 145 91' FX188 1-1/2" 1-1/2 230 3 145 91' JX188 1-1/2" 1-1/2 200-208 3 145 91' GX189 1-1/2" 2 460 3 145 110' FX189 1-1/2" 2 230 3 145 110' JX189 1-1/2" 2 200-208 3 145 110' DX185 1-1/2" 1 230 1 85 73' DX186 1-1/2" 1-1/2 230 1 58 114' DX188 1-1/2" 1-1/2 230 1 145 91' DX189 1-1/2" 2 230 1 145 110' HX188 1-1/2" 1-1/2 200-208 1 145 91' HX189 1-1/2" 2 200-208 1 145 110' DX191 1-1/2" 2 230 1 45 137' PERFORMANCE CURVES DIMENSIONS SERVICE CHECKLIST SPECIFICATIONS TDH FLOW PER MINUTE OWNER'S MANUAL Zoeller X180 & X190 Series Effluent Pumps Owners Manual SPECIFICATIONS Zoeller X180 & X190 Series Effluent Pumps Specifications TECHNICAL DATA Zoeller X180 & X190 Series Effluent Pumps Technical Data WIRING DIAGRAM Zoeller X180 & X190 Series Effluent Pumps Wiring Diagram Pump Products application engineers are standing by to help you find the right pump, as well as to provide price quotes, stocking availability and shipping information. Call our toll free number 1-800-429-0800 to speak to an expert today.

    VIEW